" ... interval. A thin copper tube closed at the lower end, reaching through the cover, extends to the bottom of the disk ; the bulb of a thermometer is inserted in this tube and measures the temperature of the disks, an oil tube runs to the centre of the... "
Railway Master Mechanic - Page 8
1881
Full view - About this book

Transactions, Issues 26-32

1879 - 676 pages
...per hour, which loss is not appreciable when observations are taken within a few seconds interval. A thin copper tube closed at the lower end, reaching through the cover, extends to the bottom of the disk ; the bulb of a thermometer is inserted in this tube, and measures the temperature of the disks...
Full view - About this book

Transactions of the American Society of Mechanical Engineers, Volume 1

American Society of Mechanical Engineers - Mechanical engineering - 1880 - 562 pages
...per hour, which loss is not appreciable when observations are taken within a few seconds' interval. A thin copper tube, closed at the lower end, reaching...the cover, extends to the bottom of the disc ; the buIb of a thermometer is inserted in this tube and measures the temperature of the discs ; an oil tube...
Full view - About this book

Proceedings, Volume 29

American Association for the Advancement of Science - Science - 1881 - 916 pages
...per hour, which loss is not appreciable when observations are taken within a few seconds' interval. A thin copper tube closed at the lower end, reaching through the cover, extends to the bottom of the disk ; the bulb of a thermometer is inserted in this tube and measures the temperature of the disks,...
Full view - About this book

Proceedings of the American Association for the Advancement of Science, Issue 29

1881 - 898 pages
...per hour, which loss is not appreciable when observations are taken within a few seconds' interval. A thin copper tube closed at the lower end, reaching through the cover, extends to the bottom of the disk; the bulb of a thermometer is inserted in this tube and measures the temperature of the disks,...
Full view - About this book

Proceedings of the American Association for the ..., Volume 29, Part 1880

American Association for the Advancement of Science - 1881 - 898 pages
...per hour, which loss is not appreciable when observations are taken within a few seconds' interval. A thin copper tube closed at the lower end, reaching through the cover, extends to the bottom of the disk ; the bulb of a thermometer is inserted in this tube and measures the temperature of the disks,...
Full view - About this book

Proceedings of the American Association for the Advancement of ..., Volume 29

American Association for the Advancement of Science - Science - 1881 - 476 pages
...loss is not appreciable when observations are taken within a few seconds' interval. A thin copper lube closed at the lower end, reaching through the cover, extends to the bottom of the disk ; the bulb of a thermometer is inserted in this tube and measures the temperature of the disks,...